InsightsCyber Resilience Act

Cyber Resilience Act: what applies since September and what comes in 2027.

Since 11 September 2026, manufacturers report actively exploited vulnerabilities within 24 hours, including for products that have long been on the market. From 11 December 2027 everything else applies. Deadlines, duties and the reporting route in one picture, checked against the regulation, the Commission guidance, BSI and IEC 62443.

30 minutes · remote · Ludwig Oswald, Munich

For
Management, product management, engineering, product security
As of
24 Oct 2026
Sources
EU, Commission, ENISA, BSI, JRC, IEC
By
Ludwig Oswald, Cloud & Solution Architect
01 In short

The answer in three points.

  1. The Cyber Resilience Act (CRA) covers hardware and software with a data connection placed on the EU market. Manufacturers must build the product securely and handle vulnerabilities throughout the support period, at least five years.
  2. Reporting applies since 11 Sep 2026, also for products already on the market: early warning within 24 hours, notification within 72 hours, through the platform of the EU Agency for Cybersecurity (ENISA). Everything else applies from 11 Dec 2027.
  3. Teams that develop to IEC 62443-4-1 already have much of it in their process. What is missing: risk assessment, software bill of materials (SBOM), coordinated vulnerability disclosure (CVD) policy, support period and the reporting route.
02 Diagram

Deadlines, duties and reporting route in one picture.

Dates on top, the product lifecycle with the CRA articles and the IEC 62443-4-1 practices in the middle, vulnerability handling and the reporting clock below.

Cyber Resilience Act for manufacturers
Cyber Resilience Act for manufacturersOn top the CRA dates: in force since 10 Dec 2024, rules for notified bodies from 11 Jun 2026, reporting under Art. 14 since 11 Sep 2026, also for products on the market, all obligations and CE marking from 11 Dec 2027. In the middle the manufacturer lifecycle in six steps: scope, risk assessment, secure design under Annex I Part I, conformity, placing on the market with a support period of at least five years, and the support period with updates and vulnerability handling. Below each step the article and the IEC 62443-4-1 practices; security management spans all steps. At the bottom vulnerability handling: intake with contact point and CVD policy, triage with the SBOM, a free security update, informing users. If a vulnerability is actively exploited or an incident is severe, reporting follows: early warning within 24 hours, notification within 72 hours, final report 14 days after the fix, one month for incidents, through the ENISA single reporting platform to the CSIRT, in Germany BSI. Evidence: technical documentation, risk assessment, SBOM, EU declaration of conformity, CVD policy, update history.CRA · DATES10.12.2024in force11.06.2026notified bodies (ch. IV)11.09.2026reporting duty (art. 14)as of 10/202611.12.2027all obligations · CEalso for products already on the marketMANUFACTURER · PRODUCT LIFECYCLEbelow each step: CRA article · IEC 62443-4-1 practiceScopeproduct · role · classart. 2 · 3 · 7 · 8Risk assessmentrisks of the productart. 13(2)–(4)SRSecure by designannex I part Idesign · code · testSD · SI · SVVConformitymodule A or third partyEU DoC · CE · annex VIIPlace on marketsupport period ≥ 5 yearsannex II · end date shownSGSupport periodannex I part IIupdates · vulnerabilitiesDM · SUMSM · security management across all steps (IEC 62443-4-1)VULNERABILITY HANDLING · ANNEX I PART IIREPORTING · ART. 14Intakecontact · CVD policyTriageSBOM · affected?Fixsecurity updateInformadvisory · usersfree · separate where feasibleduring the support period: reports from users, researchers and CSIRTs24 hearly warning72 hnotificationFinal report14 days after fixincident: 1 monthactively exploited or severe incident?ENISA single reporting platform → CSIRT (DE: BSI)EVIDENCEtechnical documentation (annex VII) · risk assessment · SBOM, at least top-level · EU declaration of conformity · CVD policy · update historyIEC 62443-4-1: SM management · SR requirements · SD design · SI implementation · SVV verification · DM issue handling · SUM update management · SG guidelines
The timeline is schematic. Below each step are the CRA article and the closest IEC 62443-4-1 practice, as orientation, not as a presumption of conformity.
03 Building blocks

Six steps, and what each requires.

Clarify the scope

Is it a product with digital elements, who is the manufacturer, which class? The Commission guidance gives criteria: web apps that run only in the browser are not a product, a locally installed client is. Your own cloud, without which a function would fail, belongs to the product as remote data processing.

  • Art. 2 and 3
  • Art. 7 and 8
  • Remote data processing

EU, Regulation (EU) 2024/2847, read 24 Oct 2026 · European Commission, guidance C(2026) 5252, read 24 Oct 2026

Assess the risks

The manufacturer assesses the cybersecurity risks of the product and feeds the result into design, development, delivery and maintenance. The assessment is part of the technical documentation and is kept up to date. IEC 62443-4-1 has a security context and a threat model, but no concept of risk assessment.

  • Art. 13(2)–(4)
  • Threat model
  • SR-1 · SR-2

EU, Regulation (EU) 2024/2847, read 24 Oct 2026 · JRC and ENISA, standards mapping, read 24 Oct 2026

Design and build securely

Annex I Part I lists the properties: no known exploitable vulnerabilities, secure by default configuration, updates, access control, confidentiality, integrity, data minimisation, availability, a small attack surface, logging, removable data. IEC 62443-4-2 covers many of them for automation components.

  • Annex I Part I
  • SD · SI · SVV
  • IEC 62443-4-2

EU, Regulation (EU) 2024/2847, read 24 Oct 2026 · IEC, 62443-4-2:2019, read 24 Oct 2026

Declare conformity

For most products the manufacturer assesses conformity itself (module A). Important products of class I need a notified body if harmonised standards are not applied in full; class II and critical products as a rule. Then the EU declaration of conformity, CE marking and technical documentation under Annex VII.

  • Module A
  • Art. 28–32
  • Annex VII
  • CE

EU, Regulation (EU) 2024/2847, read 24 Oct 2026

Set the support period

At least five years, measured by the expected time of use. The end date is shown at purchase with month and year. Each security update stays available for at least ten years. A substantial modification does not restart the period automatically; if it changes the expected time of use, the period is recalculated.

  • Art. 13(8), (9), (19)
  • Annex II

EU, Regulation (EU) 2024/2847, read 24 Oct 2026 · European Commission, guidance C(2026) 5252, read 24 Oct 2026

Handle and report vulnerabilities

Contact point and CVD policy, SBOM, fix without delay and free of charge, disclose fixed vulnerabilities. If actively exploited: early warning in 24 hours, notification in 72 hours, final report 14 days after the fix, through the ENISA platform to the coordinating computer security incident response team (CSIRT), in Germany CERT-Bund at the German Federal Office for Information Security (BSI).

  • Annex I Part II
  • Art. 14
  • PSIRT
  • CSAF

EU, Regulation (EU) 2024/2847, read 24 Oct 2026 · ENISA, single reporting platform, read 24 Oct 2026 · BSI, TR-03183-3, read 24 Oct 2026

04 Frameworks

Frameworks and deadlines.

What the implementation follows, as of 24 Oct 2026.

01

Regulation (EU) 2024/2847

In force since 10 Dec 2024. Rules for conformity assessment bodies since 11 Jun 2026, reporting under Art. 14 since 11 Sep 2026, everything else from 11 Dec 2027. Fines up to EUR 15 million or 2.5 % of worldwide annual turnover.

EU, Regulation (EU) 2024/2847, read 24 Oct 2026

02

Commission guidance

C(2026) 5252 of 27 Jul 2026, 84 pages with 67 examples, for instance on remote data processing, substantial modification, spare parts and the support period. It is formally adopted once all language versions exist. It is not binding.

European Commission, guidance C(2026) 5252, read 24 Oct 2026 · European Commission, guidance announcement, read 24 Oct 2026

03

Harmonised standards

Standardisation request M/606 of 3 Feb 2025 with 41 standards. ETSI started the approval process for 17 product-specific drafts on 13 Aug 2026. Up to 24 Oct 2026 we found no CRA standard cited in the Official Journal; until then manufacturers demonstrate the requirements themselves.

European Commission, CRA standardisation, read 24 Oct 2026 · ETSI, 13 Aug 2026, read 24 Oct 2026

04

IEC 62443-4-1 and 4-2

4-1 sets out the secure development process in eight practices, from security management to security updates. 4-2 defines the security capabilities of a component in seven foundational requirements. CENELEC is adapting both to the CRA with European amendments.

IEC, 62443-4-1:2018, read 24 Oct 2026 · IEC, 62443-4-2:2019, read 24 Oct 2026 · CEN-CENELEC, From EN IEC 62443 to CRA, read 24 Oct 2026

05

JRC and ENISA, standards mapping

The April 2024 analysis by the Commission’s Joint Research Centre (JRC) and ENISA finds quite good coverage for the 62443 series, but only for industrial automation. 4-1 lacks the concept of risk assessment. No part of the series is mapped to SBOM, CVD policy, contact address, secure by default configuration or data minimisation.

JRC and ENISA, standards mapping, read 24 Oct 2026

06

BSI TR-03183 and the German implementing act

Part 2 of the TR defines the SBOM, part 3 reports and advisories: security.txt, a reply to reporters within five working days, publication within 90 days. The Bundestag passed the implementing act on 15 Oct 2026. It makes BSI the market surveillance authority and sets out the fining procedure.

BSI, TR-03183, read 24 Oct 2026 · Bundestag, 15 Oct 2026, read 24 Oct 2026

As of 24 Oct 2026. Whether your product is in scope and which class it has is for your legal counsel to decide.

05 What we do not claim

Five common assumptions, checked.

01

“Nothing to do before December 2027.”

Reporting applies since 11 Sep 2026, also for products placed on the market before, and beyond the end of the support period.

EU, Reg. 2024/2847, Art. 69 and 71, read 24 Oct 2026 · European Commission, guidance, para. 210, read 24 Oct 2026

02

“Every vulnerability must be reported within 24 hours.”

Only actively exploited vulnerabilities and severe incidents. The clock starts when the manufacturer is reasonably certain after an initial assessment. All other vulnerabilities are fixed without delay and disclosed after the update.

EU, Reg. 2024/2847, Art. 14, read 24 Oct 2026 · European Commission, guidance, para. 213, read 24 Oct 2026

03

“Five years of support are enough.”

Five years are the floor. The yardstick is how long users are expected to use the product. The guidance says explicitly that five years are not the default.

EU, Reg. 2024/2847, Art. 13(8), read 24 Oct 2026 · European Commission, guidance, section 5, read 24 Oct 2026

04

“IEC 62443 means CRA conformity.”

JRC and ENISA find gaps, and the support period and reporting do not appear in the standard. An ISASecure or IECEE certificate is good evidence but gives no presumption of conformity.

JRC and ENISA, standards mapping, read 24 Oct 2026 · EU, Reg. 2024/2847, Art. 27, read 24 Oct 2026

05

“Our cloud is out of scope.”

A cloud the manufacturer develops itself and without which the product could not perform a function is remote data processing and belongs to the product. Pure web apps in the browser are not a product under the CRA.

European Commission, guidance, sections 2.2 and 8, read 24 Oct 2026

06 Questions

Questions about the Cyber Resilience Act.

What do we have to do now?

Set up the reporting route: register representatives on the ENISA platform, decide who assesses an exploitation and so starts the clock, and rehearse the process once. Add a contact point and a CVD policy so reports from outside reach you. This applies to products already on the market as well.

ENISA, single reporting platform, read 24 Oct 2026 · European Commission, CRA reporting, read 24 Oct 2026

Is IEC 62443-4-1 enough for the CRA?

It is a strong basis, especially in automation. You need to add the risk assessment under Art. 13, the SBOM, the CVD policy with a contact point, the support period and the reporting route. The standard is not yet harmonised for the CRA; CENELEC is working on amendments.

JRC and ENISA, standards mapping, read 24 Oct 2026 · CEN-CENELEC, From EN IEC 62443 to CRA, read 24 Oct 2026

Where do we start?

With a list of products and their class, then a gap analysis against Annex I: what the development process already delivers and what is missing. First comes what applies since September, the reporting route. By December 2027 follow the SBOM in the build, the update process, technical documentation and the declaration of conformity.

EU, Regulation (EU) 2024/2847, read 24 Oct 2026 · European Commission, guidance C(2026) 5252, read 24 Oct 2026

Read on: SSDLC and security gates · Software & Cloud · Fixed-price assessments

Terms in this article 23
Actively exploited vulnerability
A vulnerability for which there is reliable evidence that a malicious actor has exploited it. Only such vulnerabilities, besides severe incidents, trigger the reporting duty of the Cyber Resilience Act.
BSI TRTechnical Guideline of the German Federal Office for Information Security
BSI requirements on one topic, for example TR-03183 on manufacturer requirements under the Cyber Resilience Act or TR-03185 on the secure software lifecycle. They apply where a contract or a law requires them.
CE marking
The mark by which the manufacturer declares that a product meets the EU legal acts that apply to it. Under the Cyber Resilience Act also for cybersecurity, from 11 Dec 2027.
CEN, CENELEC, ETSI
The three European standardisation organisations. On the Commission’s request they develop harmonised standards, for example for the Cyber Resilience Act.
CRACyber Resilience Act, Regulation (EU) 2024/2847
EU regulation with cybersecurity requirements for products with digital elements, that is hardware and software with a data connection. Reporting duties since 11 Sep 2026, all other duties from 11 Dec 2027.
CSAFCommon Security Advisory Framework
A machine-readable format for security advisories, an OASIS standard in version 2.0 and adopted as ISO/IEC 20153. BSI recommends it to manufacturers.
CSIRTComputer Security Incident Response Team
A body that receives and coordinates security incidents. Under the Cyber Resilience Act, reports go to the coordinating CSIRT of the Member State, in Germany CERT-Bund at BSI.
CVD policyCoordinated Vulnerability Disclosure
A defined process for how a manufacturer receives, handles and, after the fix, publishes vulnerability reports. The Cyber Resilience Act requires one.
ENISAEuropean Union Agency for Cybersecurity
Among other things it runs the reporting platform of the Cyber Resilience Act and the European Vulnerability Database.
EU declaration of conformity
The manufacturer’s written statement that the product meets the applicable requirements. With it the manufacturer takes responsibility for that.
Harmonised standard
A European standard developed on the Commission’s request and published in the Official Journal. Applying it gives a presumption of conformity with the requirements it covers.
IEC 62443
A series of standards on the security of industrial automation and control systems. Part 4-1 covers the manufacturer’s secure development process, part 4-2 the security capabilities of a component.
IEC 62443-4-1, practices
The eight practices of the standard: SM security management, SR security requirements, SD secure by design, SI secure implementation, SVV verification and validation testing, DM management of security-related issues, SUM security update management, SG security guidelines.
ISASecure, IECEE
Two certification programmes for IEC 62443: they assess a manufacturer’s development process against 4-1 or a component against 4-2. A certificate is evidence, but gives no presumption of conformity under the Cyber Resilience Act.
JRCJoint Research Centre of the European Commission
The Commission’s science service. With ENISA it analysed in 2024 which standards cover the requirements of the Cyber Resilience Act.
Module Ainternal control
A conformity assessment the manufacturer carries out itself, without a notified body. Under the Cyber Resilience Act the route for most products.
Notified body
An independent assessment body that a Member State notifies to the Commission for certain conformity assessments. Under the Cyber Resilience Act needed for important products of class II and, depending on standards, class I.
PSIRTProduct Security Incident Response Team
The function at a manufacturer that receives and assesses vulnerability reports on its products, steers the fix, publishes advisories and files reports under the Cyber Resilience Act.
Remote data processing
Software the manufacturer designs or develops that runs remotely, for example in its cloud, and without which a product could not perform one of its functions. Under the Cyber Resilience Act it belongs to the product.
SBOMSoftware Bill of Materials
A machine-readable list of a product’s components with version and origin. With it a manufacturer quickly sees whether a new vulnerability affects it. The Cyber Resilience Act requires one at least for top-level dependencies.
SSDLCSecure Software Development Lifecycle
Software development in which every phase from design to operation has fixed security tasks. Not a separate process model but an addition to the existing one.
Substantial modification
A change to a product after it was placed on the market that affects compliance with the security requirements of Annex I or changes the intended purpose it was assessed for. Whoever makes it and makes the product available takes on the duties of a manufacturer.
Support period
The time during which a manufacturer handles a product’s vulnerabilities and delivers security updates. Under the Cyber Resilience Act at least five years, unless the product is expected to be used for less.

All terms in the glossary →

07 Contact

Want your reporting route in place before the first case?

In a first call we look at what your development process already delivers and what is missing by December 2027.

I use your details only to answer your enquiry. More in the privacy policy.